x
Kategoriler
Sepetim
arrow
arrow
PRO DCDC 240W 24V/48V 5A - 1
Açıklamalar
General ordering data
Version DC/DC converter
Order No. 2869050000
Type PRO DCDC 240W 24V/48V 5A
GTIN (EAN) 4064675620877
Qty. 1 pc(s).
Dimensions and weights
Depth 120 mm
Depth (inches) 4.724 inch
Height 130 mm
Height (inches) 5.118 inch
Width 43 mm
Width (inches) 1.693 inch
Net weight 840 g
Temperatures
Storage temperature -45 °C...85 °C
Operating temperature -25 °C...70 °C
Humidity at operating temperature 5 - 95% rel. humidity
Environmental Product Compliance
RoHS Compliance Status Compliant with exemption
RoHS Exemption (if applicable/known) 7a, 7cI
REACH SVHC Lead 7439-92-1
SCIP 832efd73-195b-4198-ad0c-1126d0bc238d
Input
Connection system Screw connection: pluggable
Current consumption in relation to the input voltage
Voltage type DC
Input voltage 24 V
Input current 11 A
DC input voltage range 28 ... 58 V DC
Input fuse (internal) 20A T
Input voltage, max. 34 V
Input voltage, min. 18 V
Inrush current <4 A @ Nominal input voltage
Rated input voltage 24 V DC
Recommended back-up fuse 15 A (DI) / 10A…16A (Char. B, C)
Wire connection method Screw connection
Output
Capacitive load unrestricted
Connection system Screw connection
Continuous output current @ UNominal 5 A @ 60°C, 6.25 A @ 45°C, 3.75 A @ 70°C
DCL - peak load reserve
Multiple of the rated current 600 %
Boost duration 15 ms
Mains failure bridge-over time
Mains failure bridge-over time, min. 10 ms
Input voltage type DC
Input voltage 24 V
Output current 5 A
Output voltage 48 V
Nominal output current for Unom 5 A @ 60 °C
Output power 240 W
Output voltage, max. 56 V
Output voltage, min. 28.5 V
Output voltage, note (adjustable via potentiometer on front)
Overload protection Yes
Parallel connection option yes, max. 3
Protection against inverse voltage Yes
Rated output voltage 48 V DC
Residual ripple, breaking spikes ≤ 50 mVPP @full load
Wire connection method Screw connection
General data
Adjacent No
Current limiting 150% Iout
Degree of efficiency > 90 %
Mounting position, installation notice On TS 35 mounting rail, 50 mm clearance above and below for free air supply., With a load ≥ 50 % of the rated current, keep at least 15 mm lateral spacing., The device should be mounted vertically. For other mounting directions, derating to 75% of the load must be considered.
Protection against reverse voltages from the load 60 V DC
Protection degree IP20
Short-circuit protection Yes
Start-up ≥ -40 °C
Surge voltage category II
EMC / shock / vibration
Noise emission in accordance with EN55032 Class B
Shock resistance IEC 60068-2-27 30 g in all directions
Vibration resistance IEC 60068-2-6 0.7 g
Teklif Formu
Sec Code
T-Soft E-Ticaret Sistemleriyle Hazırlanmıştır.